Page 38

"MINIATURE" Series

FEATURE INSTALLATION

Electrical Data (page 35). Description and contact arrangement (page 36). Contact insertion (page 48).

Mounting of connectors.

Wall cut-out for receptacle installation (see figure hereunder).
1 . Polarization by means of the tab of the lockwasher.
2. Polarization by means of the flats on the receptacle cup.

Dimensions

Dimensions (mm) in.
Number of contact A B C D E F G
3 and 4 (12.3).484 (18) .709 (2.7) .106 (12.7) .500 (3) .118 (13.6) .535 (11.6) .457
7 (15.3) .602 (21) .827 (2.7) .106 (16.2) .638 (3) .118 (17.1) .673 (15.1) .594

DIMENSIONS


Dimensions (mm) in.
Adapter Type Contact Number A B C D E
Threaded 3 and 4
7
(32.5)1.28
(33.5)1.32
(41.5)1.63
(42.5)1.67
(33)1.30
(34)1.34
(42)1.65
(43)1.69
(47)1.85
(49)1.93
Cable clamp 3 and 4
7
(36.5)1.44
(38)1.50
(45.5)1.79
(47)1.85
(37)1.46
(38.5)1.52
(46)1.81
(47.5)1.87
(55)2.17
(58)2.28
Gland 3 and 4 7 (39.5) 1.55
(45) 1.77
(48.5) 1.91
(54) 2.13
(40) 1.57
(45.5) 1.79
(49) 1.93
(54.5) 2.15
(61) 2.40
(72) 2.83


Dimensions

Dimensions

Dimensions

Dimensions: (mm) in.
Number of contact Plug Receptacle
A B C D mini D maxi E maxi F G H J K L M N
3 and 4 (14) .551 (15) .590 (6) .236 (3.5) .138 (6) .236 (6.7) .264 (28.5) 1.12 (32.5) 1.28 (35.5) 1.40 (11.5) .452 (18) .708 (18) .708 (20) .787 (16) .630
7 (17.5) .689 (19) .748 (7.8) .307 (5) .197 (8.5) .335 (9) .354 (29.5) 1.16 (34) 1.34 (41) 1.61 (15) .590 (20) .787 (21) .827 (23) .905 (19) .748