"STANDARD" Series, hermetic

LEAK RATE, less than 10-9/ATM./cu.cm/sec.

(100 °C) 212 °F

NUT MOUNTED RECEPTACLES, PIN INSERT.

Available with 3-4-6-4[(Ø4) .157 dia.] -8-12 or 17 contacts.

PART NUMBERS
   (2) Accessories
Shell size Number of contact (1) Complete pin insert receptacle Protection cap Replacement parts
"O" ring seal Locknut Lockwasher
1 3 5364 030 06 5369 100 06 5364 400 06 5364 460 06 5364 430 06
1 4 (Ø2) .079 dia. 5364 040 06 5369 100 06 5364 400 06 5364 460 06 5364 430 06
1 6 5364 060 06 5369 100 06 5364 400 06 5364 460 06 5364 430 06
2 4 (Ø4).157 dia.          
2 8 5364 080 06 5369 110 06 5364 410 06 5364 470 06 5364 440 06
2 12 5364 120 06 5369 110 06 5364 410 06 5364 470 06 5364 440 06
3 17          

(1) The receptacle is shipped with an "O" ring seal, locknut and lockwasher. (2) The accessories "O" ring seal, locknut and lockwasher can be supplied separately upon request.

FEATURES - INSTALLATION

Operating temperature : (-25 °C to+100 °C)-13 °Fto+212 °F (500 hours at (125 °C) .257 °F). Beyond these temperature limits, consult our Sales Engineering Office. For use with socket insert plugs of the "STANDARD" or "WEATHERPROOF" series. Choice is determined in accordance with prevalent operating conditions.

DESCRIPTION

The receptacle comprises:
- a threaded metal shell with pin contacts insulated by glass sealing. The shell carries an integral catch pin to prevent rotation when secured in position ;
- an "O" ring seal of synthetic rubber material ;
- a hex locknut with its lockwasher.
Shell size Number of contact Dimensions: (mm) in.
A B F G
1 3-4-6 (33.8) 1.33 (21) .826 (32) 1.26 (29) 1.14
2 4 (Ø4) .157-8-12 (39.8) 1.57 (27) 1.06 (38) 1.50 (35) 1.38
3 17        

Dimensions

INSTALLATION INSTRUCTIONS

The panel cut-out, as shown below, differs in accordance with panel thickness.
If this thickness is :
- between (2 and 4 mm) .079 and .157 in. : cut-out as per Figure 3;
- greater than (4 mm) .157 in. : cut-out as per Figure 4 ;
- less than (2 mm) .079 in. : consult manufacturer.
Installation

Shell size Number of contact Dimensions: (mm) in.
M N P Q R
1 3-4-6 (21.1) .830 (34) 1.34 (2,5) .098 (24,9) .980 (23) .905
2 4(Ø4) .157
8-12
(271) 1.07 (40) 1.57 (2.5) .098 (30.9) 1.22 (29) 1.14
3 17